The Spiral Vibration Damper is a motion control product used to dissipate aeolian vibration that may occur on cable spans. Using the recommended number of Spiral Vibration Dampers minimizes bending strain, protecting the cable from long-term fatigue due to aeolian vibration.

  • Not placement sensitive - can be installed anywhere on the cable away from other attachments

  • Helically-formed PVC-based rod makes impact with the cable to disrupt the aeolian vibration standing wave

  • Gripping section of the damper gently holds the cable, preventing damage from clamping forces

  • Effective over a broad range of frequencies

  • Easily installed by hand

  • Can be nested (subsetted), allowing easier installation

  • Proven through extensive field and laboratory testing

  • Thermal rating of 125ºC for continuous operation

  • Hi-Mass version provides the effectiveness of two standard SVDs

  • Recommended aeolian vibration solution for all cables 0.75" in diameter and below

Product Information

Spiral Vibration Damper for Transmission & Distribution - Catalog Pages

Spiral Vibration Damper for Communications Lines - Catalog Pages

Spiral Vibration Damper for Tower Down Guys - Catalog Pages

Spiral Vibration Damper for OPGW - Catalog Pages

 

Installation Instructions

SP2130 (Spiral Vibration Damper)

SP3278 (Multiple Spiral Vibration Dampers)

 

Reports & Manuals

Aeolian Vibration Basics

Overhead Line Distribution Repair Manual

Standard - For use on: Bare Conductors, Shield Wires and OPGW

NOTES: (1) Up to three SVD's can be subset together in one location where the cable diameter is 0.461" and below. (2) On cables with diameters above 0.461", only two SVD's should be subset for optimal damping performance.

Catalog Number    Cable Diameter Range     Length Per Carton
in mm in mm Units Wt./lb
5050104 0.327 - 0.461 8.3 - 11.6 51 1.30 50 34
5050105 0.462 - 0.563 11.7 - 14.2 53 1.35 50 36
5050106 0.564 - 0.760 14.3 - 19.3 65 1.65 50 50

 

Hi-Mass - For use on: Bare Conductors, Shield Wires and OPGW

NOTES: (1) Up to three SVD's can be subset together in one location where the cable diameter is 0.461" and below. (2) On cables with diameters above 0.461", only two SVD's should be subset for optimal damping performance.

Catalog Number    Cable Diameter Range     Length Per Carton
in mm in mm Units Wt./lb
5050200  0.250 - 0.326 6.3 - 8.3  87  2.21  50  55 
5050201  0.327 - 0.461  8.3 - 11.6 91  2.31  50  60 
5050202  0.462 - 0.563  11.7 - 14.2  94 2.39  50  65 
5050203  0.564 - 0.760   14.3 - 19.3 97 2.46  15 55 

 